Most machines are built and tested at 380 V / 50 Hz. A large share of the world runs 440 or 480 V at 60 Hz. The voltage change is a transformer or a motor re-tap. The frequency change is not.
Re-rate the drive rather than the nameplate. That means changing the pulley or the gearbox ratio so the working shaft speed stays where the chamber was designed for, and quoting motors at the site voltage and frequency rather than shipping a 50 Hz motor with a note.
Ask for the test report at the site frequency. A machine that was run-in at 50 Hz and shipped to a 60 Hz site has never been tested at the speed it will actually run.
Control transformers, VFD parameters, hour meters and thermal overload settings are all frequency-dependent. So is the hydraulic cooler fan on some models. These are cheap to change at the factory and expensive to discover during commissioning.