A cement kiln buying refuse-derived fuel cares about three things: calorific value, chlorine, and consistency. Only the first is usually discussed at the quotation stage, and it is the one most affected by equipment the supplier does not control.
Water does not burn. Every percentage point of moisture removes roughly 0.2 to 0.25 MJ/kg from the net calorific value, and municipal waste in a wet climate arrives at 35 to 45% moisture. A line that screens fines out and leaves the combustible fraction in the rain for a week will not hold its number.
Sand, glass and stone pass through most separation stages if they are the wrong size. A ballistic separator removes them by shape; a trommel removes them by size. If the specification calls for 12 MJ/kg, the inert content usually has to be under 10%.
Particle size affects how the material burns and how it can be fed, not its energy content directly. A tighter size band does improve combustion consistency and reduces kiln fluctuations, which is why kilns often specify a top size as well as a calorific value.
The last item is the one that causes disputes. A line that meets spec on a bench sample and fails in a truck is usually a sampling problem, not a process problem.