Current revision of every series we build. Each PDF lists model, chamber size, drive power, capacity and output range, with the material basis the figures were measured on.
No form required. If a number is missing for your material, send a sample description and we will issue a written capacity guarantee instead.
Capacity figures are measured on a stated material at a stated bulk density - rigid plastic at 200 kg/m3, mixed municipal waste at 350 kg/m3, for example. Every table carries that basis in the note underneath. Tire, cable and metal scrap reduce throughput by 30-50% against the plastic figure.
Chamber size sets the largest item that enters without pre-cutting. Measure your bulkiest piece before choosing.
Drive power is the installed motor rating, not the draw at the meter. Expect 60-75% of it under normal load.
Output range comes from the screen fitted. A smaller screen lowers capacity, often by a third.
Voltage and frequency are quoted at order. 60 Hz sites are re-rated rather than re-badged.
Foundation drawings, loading drawings, spare parts lists with prices, electrical schematics and the commissioning checklist are issued per order, because they depend on the site and the voltage. Ask for the package with your quotation - we send it before the deposit, not after.
Ask for the bound catalogue with the complete model list and line layouts.